Revolutionary Incubation Systems for Microscopy Platforms

 
 Whole Microscope Incubation
Zeiss  Nikon  Olympus  Leica Platforms
 
* Chamber and Stage Type Incubation
 
Our Products
 
* Chamber and Stage Based Cooling
 
Heating 
 
Cooling 
 
* Multiple CO
2
 O
2  
Gas Control Solutions
 
Gas Control
 
Our Company
 
* 1995 First Time Lapse Microscopy  Launched
 
* 2010 First Incubation Systems Developed
 
* 2017 Product Development with Oxford University
 
* 2014 Worlds First Vibration Free Incubation System
 
Our Customers Major Universities
and Research Institutes
 
Moving Parts- Reduced Reliability
 
Introduces External Dirty Air
 
No Chamber Modifications Possible
 
 Vibration
 
Traditional  Fan System
 
Limited Range  
30-42
o
C
 
 Fans-     Noisy Environment
 
Pipes-    Require more fitting space
 
* Green Technology 90% Less Power than Fan Systems
   No Moving Parts- Better Reliability
   72 Hour Replacement Policy
 
* No Support Pillars Better Access
   Panel Assembled Allows Chamber Modification
 
* Extended Temperature Range
   18-42
o
C Convection
 
* No Vibration  No Fans   No Pipes
   No Noise
 
Vibration Free- The Future
 
* Dual Convection Heaters
   No Gradients
   No Dirty Air
 
Hours       0               12               24               36               48              60              72
 
T
o 
 C
40
30
20
 
Source:
 
University of Heidelberg Germany
 
Temperature Stability Data
 
James Flewellyn
           The Francis Crick Institute London
 
 
“We use the system for live cell TIRF and epi-fluorescence imaging and magnetic
tweezer experiments. Our incubation chamber was made to fit a bespoke microscope,
MicroscopeHeaters adjusted the chamber to our needs, providing drop-in panels to
modify our microscope system through our development phase”
 
What our Clients Say About Us…..
 
Dr. Jens Eriksson,
             Uppsala University, Sweden
 
"I'm very pleased with our microscope heating system from Digital Pixel. At our
facility we are routinely running 72 hours long time lapse experiments on primary
cells without any issues with it. What really sets the system apart from any other
that I have been working with over the past 10 years, is that it is completely
silent.
 
Zeiss Confocal
University of Oxford
 
 
 
Leica DMi8 SP8
University of Southampton
 
 
 
Nikon TI-2
CrestOptics V3
University of Cambridge
 
 
 
Olympus IX83 TIRF
Demanding  Imaging
University of Oxford
 
 
 
 
Olympus IX83
PicoQuant FLIM
San Diego
 
 
 
 
Olympus IX73
Yeast Single Molecule
Imaging
University of Sussex
 
 
 
Ordering Information- Chamber Incubation and CO
2 
Control:
Model
 
   Colour       Layer Option              Microscope Modality
IX71                  CL/MB/MBC
 
        N/A
 
       WDF/CREST_v3/YOKO/CONFOCAL
IX81
 
CL/MB/MBC
 
        N/A
 
       WDF/CREST_v3/YOKO/CONFOCAL
IX73                  CL/MB/MBC
 
       1L/2L                WDF/CREST_v3/YOKO/CONFOCAL
IX83
 
CL/MB/MBC
 
       1L/2L                WDF/CREST_v3/YOKO/CONFOCAL
i.e.       IX83, 2 layers, Clear with Crest_v3   is :    IX83_CL_2L_CREST_v3        
 
Notes:
Colour:          CL=Clear     MB=Matt Black
                                           MBC= Matt Black with Clear Front
Layer             1L=  One Layer
                      2L= Two Layer Option
Microscope  WDF=Widefield              CREST_v3
                       YOKO=YOGOGAWA        CONFOCAL
Tt
 
All Systems Include:
DP_MTC_2000      Microprocessor Temperature Controller
DP_150_VF            Two Vibration Free Heater Modules.
DP-PT100_TS         Stainless Steel Temperature Sensor
Tt
 
Gas Controller
DP_CO2_MIX_0_18 
 
Microprocessor Controlled CO2 Controller 0-18% CO2 range
DP_SEAL_INSERT
 
K-Type sealed insert with glass lid, for 96 well, 35mm Petri and 75x25mm
  
slide sample holder.
OLY_STAGE_PLATE                   
Adaptor plate to for K-type to Olympus Stage
.
 
Ordering Information- Chamber Incubation and CO
2 
Control:
Model
 
   Colour       Layer Option              Microscope Modality
IX71                  CL/MB/MBC
 
        N/A
 
       WDF/CREST_v3/YOKO/CONFOCAL
IX81
 
CL/MB/MBC
 
        N/A
 
       WDF/CREST_v3/YOKO/CONFOCAL
IX73                  CL/MB/MBC
 
       1L/2L                WDF/CREST_v3/YOKO/CONFOCAL
IX83
 
CL/MB/MBC
 
       1L/2L                WDF/CREST_v3/YOKO/CONFOCAL
i.e.       IX83, 2 layers, Clear with Crest_v3   is :    IX83_CL_2L_CREST_v3        
 
Notes:
Colour:          CL=Clear     MB=Matt Black
                                           MBC= Matt Black with Clear Front
Layer             1L=  One Layer
                      2L= Two Layer Option
Microscope  WDF=Widefield              CREST_v3
                       YOKO=YOGOGAWA        CONFOCAL
Tt
 
All Systems Include:
DP_MTC_2000      Microprocessor Temperature Controller
DP_150_VF            Two Vibration Free Heater Modules.
DP-PT100_TS         Stainless Steel Temperature Sensor
Tt
 
Gas Controller
DP_CO2_MIX_0_18 
 
Microprocessor Controlled CO2 Controller 0-18% CO2 range
DP_SEAL_INSERT
 
K-Type sealed insert with glass lid, for 96 well, 35mm Petri and 75x25mm
  
slide sample holder.
OLY_STAGE_PLATE                   
Adaptor plate to for K-type to Olympus Stage
.
   
Want to Know More?  Please Get in Touch
   
Digital Pixel Cell Viability and Microscopy Solutions
Science Park Square
Brighton BN1 9SB
Tel:    0044 1273 502176
www.microscopeheaters.com
support@digitalpixel.co.uk  
Slide Note
Embed
Share

Our company specializes in cutting-edge incubation systems for microscopy platforms, offering innovative solutions like the world's first vibration-free system and a wide range of gas control options. Our products cater to major universities and research institutes, providing temperature stability data and receiving rave reviews from clients worldwide.

  • Incubation systems
  • Microscopy platforms
  • Vibration-free technology
  • Gas control solutions
  • Temperature stability

Uploaded on Oct 05, 2024 | 0 Views


Download Presentation

Please find below an Image/Link to download the presentation.

The content on the website is provided AS IS for your information and personal use only. It may not be sold, licensed, or shared on other websites without obtaining consent from the author. Download presentation by click this link. If you encounter any issues during the download, it is possible that the publisher has removed the file from their server.

E N D

Presentation Transcript


  1. Whole Microscope Incubation Zeiss Nikon Olympus Leica Platforms

  2. Our Company * 1995 First Time Lapse Microscopy Launched * 2010 First Incubation Systems Developed * 2014 Worlds First Vibration Free Incubation System * 2017 Product Development with Oxford University Our Products Heating Cooling Gas Control * Chamber and Stage Type Incubation * Chamber and Stage Based Cooling * Multiple CO2 O2 Gas Control Solutions

  3. Our Customers Major Universities and Research Institutes

  4. Traditional Fan System Vibration Pipes- Require more fitting space Fans- Noisy Environment Introduces External Dirty Air Limited Range 30-42oC No Chamber Modifications Possible Moving Parts- Reduced Reliability

  5. Vibration Free- The Future * No Vibration No Fans No Pipes No Noise * Extended Temperature Range 18-42oC Convection * Dual Convection Heaters No Gradients No Dirty Air * No Support Pillars Better Access Panel Assembled Allows Chamber Modification * Green Technology 90% Less Power than Fan Systems No Moving Parts- Better Reliability 72 Hour Replacement Policy

  6. Temperature Stability Data To C 40 30 20 Hours 0 12 24 36 48 60 72 Source: University of Heidelberg Germany

  7. What our Clients Say About Us.. James Flewellyn The Francis Crick Institute London We use the system for live cell TIRF and epi-fluorescence imaging and magnetic tweezer experiments. Our incubation chamber was made to fit a bespoke microscope, MicroscopeHeaters adjusted the chamber to our needs, providing drop-in panels to modify our microscope system through our development phase Dr. Jens Eriksson, Uppsala University, Sweden "I'm very pleased with our microscope heating system from Digital Pixel. At our facility we are routinely running 72 hours long time lapse experiments on primary cells without any issues with it. What really sets the system apart from any other that I have been working with over the past 10 years, is that it is completely silent.

  8. Zeiss Confocal University of Oxford

  9. Leica DMi8 SP8 University of Southampton

  10. Nikon TI-2 CrestOptics V3 University of Cambridge

  11. Olympus IX83 TIRF Demanding Imaging University of Oxford

  12. Want to Know More? Please Get in Touch Digital Pixel Cell Viability and Microscopy Solutions Science Park Square Brighton BN1 9SB Tel: 0044 1273 502176 www.microscopeheaters.com support@digitalpixel.co.uk