Comprehensive Reports on Chronic Congestion Management

useful reports for chronic congestion scr813 n.w
1 / 11
Embed
Share

Explore a range of useful reports related to chronic congestion management, including SCR813 updates, MIS reports, and notifications. Access valuable insights and data to enhance congestion analysis and decision-making processes.

  • Reports
  • Chronic Congestion
  • Management
  • SCR813
  • Notifications

Uploaded on | 0 Views


Download Presentation

Please find below an Image/Link to download the presentation.

The content on the website is provided AS IS for your information and personal use only. It may not be sold, licensed, or shared on other websites without obtaining consent from the author. If you encounter any issues during the download, it is possible that the publisher has removed the file from their server.

You are allowed to download the files provided on this website for personal or commercial use, subject to the condition that they are used lawfully. All files are the property of their respective owners.

The content on the website is provided AS IS for your information and personal use only. It may not be sold, licensed, or shared on other websites without obtaining consent from the author.

E N D

Presentation Transcript


  1. Useful Reports for Chronic Congestion SCR813 ECEII Changes

  2. Useful Reports For Congestion Review PUBLIC

  3. Chronic Congestion Related MIS Reports Congestion Related Reports on MIS NSA Active Constraints (NP6-6-CD) Contains contingency/element pairs beings sent to SCED for consideration in dispatching. Assessment of Chronic Congestion (NP3-767-M) ERCOT s ROS monthly report Monthly Real-Time Congestion Report - Chronic or Severe Constraints (NP6-572-ER) Provides reasons for irresolvable, highly loaded, or long duration congestion PUBLIC

  4. Chronic Congestion Find MIS Reports by Name or EMIL ID 1. Navigate to https://mis.erecot.com/secure 2. Select your Digital Certificate 3. Select Data Products from the left 4. Search for the report name or EMIL ID 4 PUBLIC

  5. Chronic Congestion NMMS_POSTINGS Reports Location On Citrix within the NMMS_POSTINGS\NMMS_MODELS folder Contained with a Zip file named NMMS_Model_Reports_CIM_xxx.zip Reports exist for each model load Line Ratings AC_LINE_RATINGS_xxx.csv Contains a row for each rating of an element. Example, the 2-hour rating for 75 would be a row A line will be repeated if it is jointly rated Line Parameters AC_LINE_PARAMETERS_xxx.csv Contains R, X, BHC, PSSE Name, PSSE Number, and more! Similar reports are present for Series Devices PUBLIC

  6. SCR813 PUBLIC

  7. SCR813 - Submitter Shown Jointly-Rated Equipment and Coordination Confirmation Requested 7 PUBLIC

  8. SCR813 - Enhanced Notifications Walking the Tree Add functionality to send notifications to model-instance owners when nearby changes are made. Line 123 Attributes: Impedances Owners: Company A Company B Currently notifications are only sent to owners of modified instances Ratings sets are only owned by one company Each company will have their own ratings set if jointly owned Example A notification would be sent to Company B if Ratings Set #1 were modified by Company A Changing the impedance will send a notification to Company A and Company B Ratings Set #1 Attributes: Static Ratings Dynamic Ratings Owner: Company A Changing the ratings in Ratings Set #1 will only send a notification to Company A Ratings Set #2 Attributes: Static Ratings Dynamic Ratings Owner: Company B Changing the ratings in Ratings Set #1 will only send a notification to Company B PUBLIC

  9. SCR813 - Additional Notification The notification currently sent when a NOMCR is submitted would also be sent to all associated companies 9 PUBLIC

  10. ECEII NPRR902 PUBLIC

  11. ECEII and NMMS_M_IMM_ECEII New role required to access ECEII data PTC Postings which will require new role: TSP version of CIM Network Model TSP version of Test Network Operations Model Redacted CIM Network Model Standard Contingency List (NP5- 615-SG) will be classified as ECEII 11 PUBLIC

More Related Content