External Libraries

 
External Libraries
Quick summary
 
Peter Mason
March 2017
 
Step 1 – Collect library spectra
 
You’re in charge
Of validation and quality control
Collect them outside of TSG
TSG likes ENVI Spectral Library format
…Or collect them in TSG’s Scratchpad
Collect enough spectra
Cover what you expect to find
Unmixing generally doesn’t work well with too few minerals
SWIR generally requires more than one spectrum per mineral
SWIR can actually work at a finer level – more than one “
class
” per
mineral – and more than one spectrum per “class” is strongly
recommended here
 
Step 2 – Mark up the spectrum names
 
TableIndex
Links to TSG’s mineral table
If you don’t have this table – ask us
Every
 spectrum must have a
TableIndex markup
Contact us if your mineral  isn’t in
the table
ClassIndex
For SWIR “classes”
E.g., to have two slightly different
muscovite items at the unmixing level
None, or every spectrum
Your
 class numbers
just provide different numbers for
different classes
 
Step 3 – Get the library into TSG
format
 
TSG’s Scratchpad can save in TSG format
Check out the file-type list when saving
TSG’s scratchpad can do a quick import of an ENVI
spectral library
Drag & drop
Resamples to the main dataset’s wavelengths if necessary
Otherwise import the library
 
Step 4 – Use it! (1 / 4)
 
Traditional method:
1.
Open your “main” dataset in TSG
2.
“Attach” your library
Go to the Spectrum screen
For a dataset pair, click 
Primary
 /
Assoc 
at top left until the “right”
spectral range is plotted (e.g.,
Vis-SWIR spectra for a SWIR library)
 
File -> Attach Aux…
 
 
Easier:
1.
Open your main dataset in TSG and put up a floater.
2.
For a pair, associate the floater with the “right” dataset (e.g., Vis-SWIR dataset
for a SWIR aux library).         Toolbar button.
3.
From Windows Explorer, 
drag & drop 
the aux library’s .TSG file onto the floater.
 
Step 4 – Use it! (2 / 4)
 
3.
Confirm the wavelength subsetting
File -> Settings [Aux]
These days (2019…) this is brought up automatically after an attach
Only the 
Subset
 settings are of concern here (normally 
turn off Subset
)
 
Step 4 – Use it! (3 / 4)
 
4.
Optionally do Domain RMS editing
 
Step 4 – Use it! (4 / 4)
 
5.
Produce a result
Edit -> New scalar
CLS
 (bottom of the list)
You’ll find the result scalars in the 
Assemblages and Auxmatch
 group
 
Step 5 – See it (1 / 3)
 
Floater TSA mode
 
Step 5 – See it (2 / 3)
 
Summary screen
 
Step 5 – See it (3 / 3)
 
Log screen
 
 
 
 
 
Scatter screen
Slide Note
Embed
Share

This guide provides step-by-step instructions on collecting, marking up, formatting, and using spectral libraries, focusing on validation and quality control. It covers the process from collecting library spectra to integrating them into TSG format for effective utilization in data analysis.

  • External Libraries
  • Spectral Data
  • Data Integration
  • Quality Control
  • Data Analysis

Uploaded on Feb 18, 2025 | 0 Views


Download Presentation

Please find below an Image/Link to download the presentation.

The content on the website is provided AS IS for your information and personal use only. It may not be sold, licensed, or shared on other websites without obtaining consent from the author.If you encounter any issues during the download, it is possible that the publisher has removed the file from their server.

You are allowed to download the files provided on this website for personal or commercial use, subject to the condition that they are used lawfully. All files are the property of their respective owners.

The content on the website is provided AS IS for your information and personal use only. It may not be sold, licensed, or shared on other websites without obtaining consent from the author.

E N D

Presentation Transcript


  1. External Libraries Quick summary Peter Mason March 2017

  2. Step 1 Collect library spectra You re in charge Of validation and quality control Collect them outside of TSG TSG likes ENVI Spectral Library format Or collect them in TSG s Scratchpad Collect enough spectra Cover what you expect to find Unmixing generally doesn t work well with too few minerals SWIR generally requires more than one spectrum per mineral SWIR can actually work at a finer level more than one class per mineral and more than one spectrum per class is strongly recommended here

  3. Step 2 Mark up the spectrum names TableIndex Links to TSG s mineral table If you don t have this table ask us Every spectrum must have a TableIndex markup Contact us if your mineral isn t in the table ClassIndex For SWIR classes E.g., to have two slightly different muscovite items at the unmixing level None, or every spectrum Your class numbers just provide different numbers for different classes

  4. Step 3 Get the library into TSG format TSG s Scratchpad can save in TSG format Check out the file-type list when saving TSG s scratchpad can do a quick import of an ENVI spectral library Drag & drop Resamples to the main dataset s wavelengths if necessary Otherwise import the library

  5. Step 4 Use it! (1 / 4) Traditional method: 1. Open your main dataset in TSG 2. Attach your library Go to the Spectrum screen For a dataset pair, click Primary / Assoc at top left until the right spectral range is plotted (e.g., Vis-SWIR spectra for a SWIR library) File -> Attach Aux Easier: 1. 2. Open your main dataset in TSG and put up a floater. For a pair, associate the floater with the right dataset (e.g., Vis-SWIR dataset for a SWIR aux library). Toolbar button. From Windows Explorer, drag & drop the aux library s .TSG file onto the floater. 3.

  6. Step 4 Use it! (2 / 4) 3. Confirm the wavelength subsetting File -> Settings [Aux] These days (2019 ) this is brought up automatically after an attach Only the Subset settings are of concern here (normally turn off Subset)

  7. Step 4 Use it! (3 / 4) 4. Optionally do Domain RMS editing

  8. Step 4 Use it! (4 / 4) 5. Produce a result Edit -> New scalar CLS (bottom of the list) You ll find the result scalars in the Assemblages and Auxmatch group

  9. Step 5 See it (1 / 3) Floater TSA mode

  10. Step 5 See it (2 / 3) Summary screen

  11. Step 5 See it (3 / 3) Log screen Scatter screen

Related


More Related Content

giItT1WQy@!-/#giItT1WQy@!-/#giItT1WQy@!-/#giItT1WQy@!-/#giItT1WQy@!-/#