Efficient Hydronic Comfort Systems for Sustainable Building Solutions

 
Hydronic Comfort Systems
Increase and Maintain
Building Efficiency
 
For the Life of Your Building
 
www.hia-c.org
 
Safe and Reliable
 
Multiple Comfort Options
Low refrigerant content
Reduce refrigerant in the building by 75% over split
refrigerant systems
Low or no refrigerant in tenant space or corridors
No refrigerant sensors required in baseboard
Refrigerant is regulated 
BUY certified factory-
sealed refrigerant circuits
Improve Efficiency and cut Refrigerant Volume
with Hydronic Central Systems
 
Productivity
Simultaneous and cyclical
   heating or cooling/reclaim
 Comfort on demand
Choice of air or radiant
Indoor Air Quality
Avoid cross contamination of airflow
Filtration choices and options
Humidify – dehumidify – control odor - ventilate
 
Comfortable & Productive
 
Sustainability
 for life
 
Preserve the investment in Efficiency
Component availability and compatibility
Competition controls COSTS
System options
Service for life
Replacement choices
Hydronic component life
20–100 years – your choice
Reclaim, Recycle, Simplify for Life
 
Long Term Solutions
 
Compatibility for life
Technology and efficiency
Equipment and components
Integrated solutions for the total building
Net energy use, infrastructure, and operating cost
total building HVAC and hot water.
New Construction – Pipe uses less space
Renovation/Remodel/Repurpose
 
Energy Efficient
 
Highest Building efficiency
Lowest BTU transport cost
Water uses less kW to move Btu’s in the building
Water maintains efficiency versus outdoor temperature
Variable flow & temperature matched to demand
Integrated Design Process
Energy sharing / HVAC and Hot Water
Whole building approach by design team
Path to Net Zero:  Use less energy, store more, reclaim,
integrate, and operate the system for profit
IEER is a test procedure
 
In a lab – not your building – integrated and weighted as prescribed
Cooling test only includes 2% at 95F and 40% RH as worst case.  98% of rating is
from 65-81.5⁰F outdoor air temperature.
Heating test not lower than 16F / Air flow varied down to 25%
Lab refrigerant pipe – not field Length, flat no lift to the roof
Cooling temperature room set point at 80°F with 50% relative humidity
People generate moisture to be removed…  Who is happy at 80F?
Performance measured after lab maintained conditions for an hour
Allows refrigerant circuit to balance - this does not happen in your building
IEER is a test – an equipment comparison – It must be de-rated when applied
When the compressor becomes the system PUMP it gives up efficiency – up to 30%
plus operation outside test conditions requires additional de-rates…
Commercial Buildings are unique
Design for the life of the building with Water
 
Reduce Installed Cost
Lowest Operating Cost
Retained Value
Building Resale Value
The utility bill is a relevant operating cost
hydronic components are for the life of the building
Adaptable, replaceable, upgradeable
Choice in first cost and 
all the budgets
!
 
Budget + Return on Investment
 
(
reduced equipment life destroys ROI)
 
For the Life of the Building
 
Flexible – 4, 2, and 1-pipe designs
Adaptable to technology
forward and backward compatibility
Upgradeable at any time
Versatile – easy to change
Once built our Hydronic Mechanical Infrastructure
will support and preserve your investment in
efficiency, comfort and productivity.
www.hia-c.org
 
www.hia-c.org
 
Water: The Natural Choice
Slide Note
Embed
Share

Hydronic comfort systems offer safe, reliable, and sustainable solutions for maintaining building efficiency and increasing comfort levels. These systems use water as a natural choice, reducing refrigerant content and improving energy efficiency. They provide multiple comfort options, ensure productivity, and enhance indoor air quality while promoting sustainability for the life of the building. With long-term solutions and energy-efficient designs, hydronic systems offer a holistic approach to building management, aiming for net-zero energy use. Water truly is the natural choice for efficient and sustainable building solutions.

  • Hydronic systems
  • Sustainable buildings
  • Energy efficiency
  • Indoor air quality
  • Building comfort

Uploaded on Sep 21, 2024 | 0 Views


Download Presentation

Please find below an Image/Link to download the presentation.

The content on the website is provided AS IS for your information and personal use only. It may not be sold, licensed, or shared on other websites without obtaining consent from the author. Download presentation by click this link. If you encounter any issues during the download, it is possible that the publisher has removed the file from their server.

E N D

Presentation Transcript


  1. Hydronic Comfort Systems Increase and Maintain Building Efficiency For the Life of Your Building www.hia-c.org Water is the Natural Choice

  2. Safe and Reliable Multiple Comfort Options Low refrigerant content Reduce refrigerant in the building by 75% over split refrigerant systems Low or no refrigerant in tenant space or corridors No refrigerant sensors required in baseboard Refrigerant is regulated BUY certified factory- sealed refrigerant circuits Improve Efficiency and cut Refrigerant Volume with Hydronic Central Systems Water is the Natural Choice

  3. Comfortable & Productive Productivity Simultaneous and cyclical heating or cooling/reclaim Comfort on demand Choice of air or radiant Indoor Air Quality Avoid cross contamination of airflow Filtration choices and options Humidify dehumidify control odor - ventilate Water is the Natural Choice

  4. Sustainability for life Preserve the investment in Efficiency Component availability and compatibility Competition controls COSTS System options Service for life Replacement choices Hydronic component life 20 100 years your choice Reclaim, Recycle, Simplify for Life Water is the Natural Choice

  5. Long Term Solutions Compatibility for life Technology and efficiency Equipment and components Integrated solutions for the total building Net energy use, infrastructure, and operating cost total building HVAC and hot water. New Construction Pipe uses less space Renovation/Remodel/Repurpose Water is the Natural Choice

  6. Energy Efficient Highest Building efficiency Lowest BTU transport cost Water uses less kW to move Btu s in the building Water maintains efficiency versus outdoor temperature Variable flow & temperature matched to demand Integrated Design Process Energy sharing / HVAC and Hot Water Whole building approach by design team Path to Net Zero: Use less energy, store more, reclaim, integrate, and operate the system for profit Water is the Natural Choice

  7. IEER is a test procedure In a lab not your building integrated and weighted as prescribed Cooling test only includes 2% at 95F and 40% RH as worst case. 98% of rating is from 65-81.5 F outdoor air temperature. Heating test not lower than 16F / Air flow varied down to 25% Lab refrigerant pipe not field Length, flat no lift to the roof Cooling temperature room set point at 80 F with 50% relative humidity People generate moisture to be removed Who is happy at 80F? Performance measured after lab maintained conditions for an hour Allows refrigerant circuit to balance - this does not happen in your building IEER is a test an equipment comparison It must be de-rated when applied When the compressor becomes the system PUMP it gives up efficiency up to 30% plus operation outside test conditions requires additional de-rates Commercial Buildings are unique Design for the life of the building with Water Water is the Natural Choice

  8. Budget + Return on Investment (reduced equipment life destroys ROI) Reduce Installed Cost Lowest Operating Cost Retained Value Building Resale Value The utility bill is a relevant operating cost hydronic components are for the life of the building Adaptable, replaceable, upgradeable Choice in first cost and all the budgets! Water is the Natural Choice

  9. For the Life of the Building Flexible 4, 2, and 1-pipe designs Adaptable to technology forward and backward compatibility Upgradeable at any time Versatile easy to change Once built our Hydronic Mechanical Infrastructure will support and preserve your investment in efficiency, comfort and productivity. www.hia-c.org Water is the Natural Choice

  10. Water: The Natural Choice www.hia-c.org Water is the Natural Choice

Related


More Related Content

giItT1WQy@!-/#giItT1WQy@!-/#giItT1WQy@!-/#giItT1WQy@!-/#giItT1WQy@!-/#