Learn about moisture control, temperature management, and troubleshooting tips for a co-composting facility in Kenya. Ensure proper moisture content between 40% to 60%, monitor temperature changes weekly, and troubleshoot odor and climatic influences effectively. Follow user guides and protocols for efficient facility maintenance.
Download Presentation
Please find below an Image/Link to download the presentation.
The content on the website is provided AS IS for your information and personal use only. It may not be sold, licensed, or shared on other websites without obtaining consent from the author. Download presentation by click this link. If you encounter any issues during the download, it is possible that the publisher has removed the file from their server.
E N D
Presentation Transcript
UBSUP - DTF project - KENYA Maintenance of a co-composting facility 9/25/2024 1
Moisture control User s guide page 11 Moisture content should be maintain between 40 to 60% 9/25/2024 2
Temperature control User s guide page 10 and 11 1st week: temperature rises quickly up to 65 C Next 6 weeks: temperature decreases gradually up to ambient temperature Next 4 weeks: temperature stabilize at ambient temperature 9/25/2024 3
Temperature control User s guide page 10 and 11 Steps: Push a hole in the middle of the windrow with a stick Attach a thermometer to a stick with a piece of string Insert thermometer in the hole and leave it for 1 minute Read the temperature and monitor with the diagram Read temperature: Daily during the first week Then 2 to 3 times per week 9/25/2024 4
Trouble shooting: composting parameters User s guide page 16 Temperature: Odour: 9/25/2024 5
Trouble shooting: climatic influences and vectors User s guide page 17 9/25/2024 6
Trouble shooting: climatic influences and vectors User s guide page 18 9/25/2024 7