Analysis of 20T Hybrid Block-Coil V5.8 Magnetic Model

Slide Note
Embed
Share

This analysis focuses on the magnetic model of a 20T hybrid block-coil V5.8 system, including modifications to incorporate ribs, iron components, rigid boundaries, component bonding, sliding and separating configurations, and stress evaluations. The study explores the layout adjustments, peak magnetic field strengths, Lorentz forces, and stress distributions within the system. Different aspects such as rigid structures, sliding coil blocks, and bonding of components are investigated to understand the performance and behavior of the hybrid block-coil system under varying conditions.


Uploaded on Sep 29, 2024 | 0 Views


Download Presentation

Please find below an Image/Link to download the presentation.

The content on the website is provided AS IS for your information and personal use only. It may not be sold, licensed, or shared on other websites without obtaining consent from the author. Download presentation by click this link. If you encounter any issues during the download, it is possible that the publisher has removed the file from their server.

E N D

Presentation Transcript


  1. 20T hybrid block-coil V5.8 E. Rochepault 14/09/2022

  2. MAGNETIC MODEL 5.8.2 Magnetic layout modified to: split the Nb3Sn blocks in 2 incorporate ribs in between (no magnetic optimization) With iron: 20.2 T in the bore 21.0 T peak field 20 T hybrid block-coil 29/09/2024 Page 2

  3. RIGID BOUNDARIES Fixed nodes (= infinitely rigid) everywhere but the coil blocks Lorentz forces only With iron Sx Sy 60 MPa 113 MPa 20 T hybrid block-coil 29/09/2024 Page 3

  4. ALL COMPONENTS BONDED, COIL SLIDING All surrounding components bonded Coil shims bonded to coils Coil blocks sliding Rigid structure Peak stresses in corners Sx Sy 373 MPa 444 MPa 20 T hybrid block-coil 29/09/2024 Page 4

  5. COMPONENTS SLIDING AND SEPARATING All surrounding components bonded Coil blocks sliding and separating Main rib bonded to YPad Some coil blocks sliding with no separation to improve convergence High bending of main rib Sx Sy 307 MPa 619 MPa 20 T hybrid block-coil 29/09/2024 Page 5