Best Practices for Disinfection and Sterilization in Healthcare Settings

Slide Note
Embed
Share

Explore the application of disinfection and sterilization in various healthcare settings like outpatient facilities, physical therapy, hydrotherapy, gym areas, and portable equipment. Learn about the importance of following strict infection control practices, cleaning protocols, and disinfectant recommendations to ensure patient safety and prevent the spread of infections.


Download Presentation

Please find below an Image/Link to download the presentation.

The content on the website is provided AS IS for your information and personal use only. It may not be sold, licensed, or shared on other websites without obtaining consent from the author. Download presentation by click this link. If you encounter any issues during the download, it is possible that the publisher has removed the file from their server.



Uploaded on Apr 03, 2024 | 0 Views


Presentation Transcript


  1. G Application of Disinfection and Sterilization Module G Module G

  2. G Application of Disinfection and Sterilization Objectives Discuss principals of disinfection and sterilization for medical devices used in outpatient facilities

  3. G Application of Disinfection and Sterilization Physical Therapy High risk patients (wounds, burns, trauma) Patient movement Strict adherence to infection control practices

  4. G Application of Disinfection and Sterilization Physical Therapy-Hydrotherapy Drain after each use, clean according to manufacturer s instructions for use Patients should be free of open lesions or wounds For non-intact skin disinfect with intermediate-level disinfectants after each use

  5. G Application of Disinfection and Sterilization Gym/Activities Room Splinting tanks emptied and cleaned weekly The hot pack hydrocollator emptied, cleaned every 2 weeks. Assure water temp >160 F ColPac is cleaned biannually, temperature monitored daily (10-21 F)

  6. G Application of Disinfection and Sterilization Gym/Activities Room Frequently used items (hand weights, parallel bars, stair rails, and canes) cleaned after each use, and weekly Wheelchairs, cuff weights, and mats wiped down with an EPA-registered disinfectant weekly or when visibly soiled Patients using PT or rehab areas with shared equipment should perform hand hygiene upon entry and exit

  7. G Application of Disinfection and Sterilization Portable Equipment Pulse oximeter Blood pressure cuff Stethoscope Clean after patient use

  8. G Application of Disinfection and Sterilization Disinfection of Computer Keyboards Keyboards can be effectively disinfected using most EPA registered disinfectants (for example): Quaternary ammonium compounds 70% isopropyl alcohol Phenolic Current recommendations are to disinfect keyboards daily and when visible soiled

  9. G Application of Disinfection and Sterilization Cleaning Toys Toys should be: Washable, Non-porous and durable Inspected for damage Cleaned with: Soap and water Rinsed with tap water and dried OR Wiped with either an: EPA-registered disinfectant 70% alcohol Dilute bleach Rinsed prior to use

  10. G Application of Disinfection and Sterilization Pharmacy Perform hand hygiene: Upon arrival at work After eating, drinking or handling food After using the toilet Prior to preparing IV medications When repackaging and handling medications When returning from outside pharmacy area

  11. G Application of Disinfection and Sterilization Pharmacy Avoid direct hand contact with medications Use counting trays, spatulas or other counting devices Clean counting trays at the start of each shift and when visible soiled

  12. G Application of Disinfection and Sterilization Medication Preparation and Storage Must be a clean, dedicated area > 3 feet from sink Free of clutter Cleaned after each shift and with any medication spills 3 ft No food, drink or specimens stored in refrigerators/freezers with pharmaceuticals Medication refrigerators/freezers should be continuously monitored to ensure temperature within proper range

  13. G Application of Disinfection and Sterilization Phlebotomy Station Needle box on the wall is above the patient s chair Clean items are stored within splash range (<3 feet from sink) Drink can is on the counter by patient card plate machine Needle boxes are unsecured by the sink Clean and dirty are poorly defined (no clear signs) Patient chair and trash can are blocking access to the sink

  14. G Application of Disinfection and Sterilization Thermometers Electronic thermometers - rectal (red) or oral (blue) New disposable hard plastic sheath for each patient Cord, probe, and unit cleansed daily and when visibly soiled according to manufacturer instructions for use Do not place unit on surfaces in patient/exam room Alternatives for ambulatory care are disposable thermometers

  15. G Application of Disinfection and Sterilization Modes of transmission Ear and Temporal Scan Thermometers New plastic cover each use Unit (especially end of probe membrane) wiped daily and when visibly soiled per manufacturer s recommendations

  16. G Application of Disinfection and Sterilization Ear, Nose and Throat (ENT) Equipment Reusable ear specula and curettes Washed with detergent and water and autoclave. Reusable nasal specula Clean and autoclave after each patient use Non disposable tips on audioscopes/tympanometers Cleaned/disinfected per manufacturer instructions for use (IFUs)

  17. G Application of Disinfection and Sterilization Eye Equipment and Drops Slit lamps Head rests, chin rests, and handles disinfected per manufacturer instructions between patient uses Eye Drops Read label (single vs multi patient use) If multi-patient, take steps to prevent contamination (i.e., no contact with eye or eyelid) Cannot be used on multiple patients Suspicion of contamination discard after single use

  18. G Application of Disinfection and Sterilization ECG Cables and Leads Cables and leads wiped with EPA-registered disinfectant after each use Clean machine at least weekly and when visibly soiled

  19. G Application of Disinfection and Sterilization Vaginal Specula Should be cleaned with detergent and water Follow manufacturer s instructions for reprocessing (i.e., HLD or steam sterilization) Stored in a manner that prevents contamination

  20. G Application of Disinfection and Sterilization Diaphragm Fitting Rings Clean with enzymatic or non- enzymatic detergent and rinse Immersed in high-level disinfectant or steam sterilization Follow manufacturer's recommendations

  21. G Application of Disinfection and Sterilization Cryosurgical Probes Cleaned with soap and water or enzymatic cleaner Immersed in high-level disinfectant Wrapped in high-level disinfectant soaked cloths Follow manufacturer s instructions

  22. G Application of Disinfection and Sterilization Vaginal Ultrasound Probes Remove sheath (i.e., probe cover, condom sheath) Pre-clean probe High level disinfect Rinse and/or dry Follow manufacturer s directions for process, time, temperature, rinsing and storage

  23. G Application of Disinfection and Sterilization Prostate Biopsy Probe Fully disposable prostate biopsy equipment is preferred. If reusable do the following: Remove the needle guide Clean probe and guide Flush all lumens with enzymatic or instrument detergent Rinse and dry High level disinfect Ensure all internal channels and lumens are expose to disinfectant Rinse with sterile water OR tap water followed by alcohol rinse PROBE MUST BE DRY PRIOR TO STORAGE

  24. G Application of Disinfection and Sterilization Channeled Endoscopes Completely immerse Perfuse HLD through lumen with syringe Connect a syringe to the port and flush until no air exits

  25. G Application of Disinfection and Sterilization Infrared Coagulation Unit Wipe to remove visible soil Clean and/or disinfect per manufacturer instructions for use (IFUs)

  26. G Application of Disinfection and Sterilization Knowledge Check True or False? Correct disinfection practice, in the outpatient setting, includes all of the following: Shared patient care equipment should be cleaned after each use Medications should be prepared in a clean, dedicated area that is free from clutter Manufacturer s instructions should be followed for cleaning and disinfecting patient care equipment Single dose vials can be reused if they are not contaminated. True False

  27. G Application of Disinfection and Sterilization Congratulations on completing the modules!

Related


More Related Content