Efficient Stack Emission Monitoring Procedure for Air Quality Control

undefined
 
Stack Emission Monitoring Procedure
 
By Perfect Pollucon Services
undefined
 
Stack Emission Monitoring Procedure
 
Stack Emission monitoring procedure includes tasks of Measurement, testing,
sampling and analysis. Onsite determination of physical parameters of flue gases
such as temperature, flow and pressure also involved in Stack emission monitoring
Air Quality is major environmental responsibility for all manufacturing industries.
Those industries can use air quality monitoring or stack monitoring to measure
degree of pollutants or contaminants present in current exhaust air and take
required steps to reduce them
All industries must have sampling port built into their stack and permanent
sampling platform to ease Stack Emission Monitoring Procedure for environmental
consultants who perform monitoring of stack emission
undefined
 
Selection of Sampling Site in Stack Emission Monitoring Procedure
 
The objective of sampling in Stack
Emission Monitoring Procedure is to
determine accurate degree of pollutants
present in air emitted from stack. Laminar
flow should be present in stack to get
accurate readings.
To select representative sample sampling
point should be at least eight stack
diameter downstream and two stack
diameter upstream from any joint, bend,
expansion and contraction.
undefined
 
Stack Emission Monitoring Procedure
 
:Travers Point
 
As per new Notifications all stacks must have sampling post and sampling
platform. Location of traverse points will be decided by pollution control
board.
After previous criteria met, to determine the minimum traverse points
required first diameter of stack is to be calculated in case of circular
stack. Also it should be far 3cm from stack wall.
Know more about how to select Traverse Point in stack monitoring
undefined
 
Molecular weight Determination
 
Molecular weight can be found by drawing known amount of gas into gas
chromatograph or Orsat apparatus. Moisture should be found. Molecular
weight can be calculated by knowing gas components.
The average molecular weight can be determined by using below mentioned
formula:
M = ∑ (i=1)^n (xi Mi)
X is mole fraction and Mi is mole weight of each constituents in mixture of
number of constituents.
undefined
 
Stack Emission Monitoring Procedure: 
Velocity Determination
 
Once Pitot tube is connected Dynamic and static pressure is found using
manometer. Also Temperature inside duct is also measured. The velocity
of gas and amount of air can be found using formula
 
 
Learn Advantages of Stack Emission testing
You can also use our stack monitoring calculators to calculate velocity of
gases online.
undefined
 
Stack Emission Monitoring Procedure: 
Moisture Determination
 
Moisture can be determined by dry and wet bulb temperature and the
referring to psychometric chart. Also condenser method work well for almost
all gas streams and comparatively easy to perform.
undefined
 
Condenser Method to determine moisture in gas stream
 
In this process sample of the stack is extracted through a filter to remove
particulate matter then through condenser, collecting the condensate
formed in the process and then it is measured.
undefined
 
Wet/Dry method to determine moisture in gas stream
 
The equilibrium temperature attained by water which is vaporising
into a gas of constant composition and constant dry bulb is called
as wet bulb temperature. The amount of depression of wet bulb
temperature below the dry bulb is the saturation degree of
humidity of the gas. Hence, moisture content of gas can be
determined by using wet and dry bulb method.
undefined
 
Sample Recovery
 
After the sample has cooled, brush down the dust on side of nozzle into
thimble and replace it in labelled container.
This blog is written by Perfect Pollucon Services. They
offer 
Environmental services
 in India including Consultancy and Monitoring
Services.
undefined
 
Thank you
Slide Note
Embed
Share

Stack emission monitoring is crucial for industries to assess and reduce pollutants in exhaust air. This procedure involves tasks like measurement, testing, and analysis of flue gases. Sampling sites are selected strategically for accurate readings, and molecular weight and gas velocity are determined for comprehensive analysis. Learn more about the importance and steps involved in stack emission monitoring for maintaining environmental responsibility.


Uploaded on Jul 11, 2024 | 1 Views


Download Presentation

Please find below an Image/Link to download the presentation.

The content on the website is provided AS IS for your information and personal use only. It may not be sold, licensed, or shared on other websites without obtaining consent from the author. Download presentation by click this link. If you encounter any issues during the download, it is possible that the publisher has removed the file from their server.

E N D

Presentation Transcript


  1. Stack Emission Monitoring Procedure By Perfect Pollucon Services Read more at: https://www.ppsthane.com Perfect Pollucon Services

  2. Stack Emission Monitoring Procedure Stack Emission monitoring procedure includes tasks of Measurement, testing, sampling and analysis. Onsite determination of physical parameters of flue gases such as temperature, flow and pressure also involved in Stack emission monitoring Air Quality is major environmental responsibility for all manufacturing industries. Those industries can use air quality monitoring or stack monitoring to measure degree of pollutants or contaminants present in current exhaust air and take required steps to reduce them All industries must have sampling port built into their stack and permanent sampling platform to ease Stack Emission Monitoring Procedure for environmental consultants who perform monitoring of stack emission Perfect Pollucon Services

  3. Selection of Sampling Site in Stack Emission Monitoring Procedure The objective of sampling in Stack Stack Monitoring Emission Monitoring Procedure is to determine accurate degree of pollutants present in air emitted from stack. Laminar flow should be present in stack to get accurate readings. To select representative sample sampling point should be at least eight stack diameter downstream and two stack diameter upstream from any joint, bend, expansion and contraction. Perfect Pollucon Services

  4. Stack Emission Monitoring Procedure:Travers Point As per new Notifications all stacks must have sampling post and sampling platform. Location of traverse points will be decided by pollution control board. After previous criteria met, to determine the minimum traverse points required first diameter of stack is to be calculated in case of circular stack. Also it should be far 3cm from stack wall. Know more about how to select Traverse Point in stack monitoring Perfect Pollucon Services

  5. Molecular weight Determination Molecular weight can be found by drawing known amount of gas into gas chromatograph or Orsat apparatus. Moisture should be found. Molecular weight can be calculated by knowing gas components. The average molecular weight can be determined by using below mentioned formula: M = (i=1)^n (xi Mi) X is mole fraction and Mi is mole weight of each constituents in mixture of number of constituents. Perfect Pollucon Services

  6. Stack Emission Monitoring Procedure: Velocity Determination Once Pitot tube is connected Dynamic and static pressure is found using manometer. Also Temperature inside duct is also measured. The velocity of gas and amount of air can be found using formula Learn Advantages of Stack Emission testing You can also use our stack monitoring calculators to calculate velocity of gases online. Perfect Pollucon Services

  7. Stack Emission Monitoring Procedure: Moisture Determination Moisture can be determined by dry and wet bulb temperature and the referring to psychometric chart. Also condenser method work well for almost all gas streams and comparatively easy to perform. Perfect Pollucon Services

  8. Condenser Method to determine moisture in gas stream In this process sample of the stack is extracted through a filter to remove particulate matter then through condenser, collecting the condensate formed in the process and then it is measured. Perfect Pollucon Services

  9. Wet/Dry method to determine moisture in gas stream The equilibrium temperature attained by water which is vaporising into a gas of constant composition and constant dry bulb is called as wet bulb temperature. The amount of depression of wet bulb temperature below the dry bulb is the saturation degree of humidity of the gas. Hence, moisture content of gas can be determined by using wet and dry bulb method. Perfect Pollucon Services

  10. Sample Recovery After the sample has cooled, brush down the dust on side of nozzle into thimble and replace it in labelled container. This blog is written by Perfect Pollucon Services. They offer Environmental services in India including Consultancy and Monitoring Services. Perfect Pollucon Services

  11. Thank you Perfect Pollucon Services