Power System Analysis Lecture: Transient Stability with Prof. Tom Overbye

undefined
 
E
C
E
 
4
7
6
P
o
w
e
r
 
S
y
s
t
e
m
 
A
n
a
l
y
s
i
s
 
L
e
c
t
u
r
e
 
2
3
:
 
T
r
a
n
s
i
e
n
t
 
S
t
a
b
i
l
i
t
y
 
Prof. Tom Overbye
Dept. of Electrical and Computer Engineering
University of Illinois at Urbana-Champaign
overbye@illinois.edu
 
A
n
n
o
u
n
c
e
m
e
n
t
s
 
Please read Chapters 11
HW 10 is 11.1, 11.4, 11.12, 11.19, 11.21; quiz on Dec
1 (hence it will not be turned in)
We will be dropping your lowest two HW and/or Quiz scores
Chapter 6 Design Project 1 is assigned.  It will count as
three regular home works and is due on Dec 3.
For tower configurations assume a symmetric conductor spacing, with the distance
in feet given by the following formula:  (Last two digits of your EIN+150)/10.
Example student A has an UIN of xxx65.  Then his/her spacing is (65+150)/10 =
21.50 ft.
Final exam is on Monday December 12, 1:30-4:30pm
 
 
1
 
P
o
w
e
r
 
S
y
s
t
e
m
 
T
i
m
e
 
S
c
a
l
e
s
 
a
n
d
T
r
a
n
s
i
e
n
t
 
S
t
a
b
i
l
i
t
y
 
Image source: P.W. Sauer, M.A. Pai, Power System Dynamics and Stability, 1997, Fig 1.2, modified
 
2
 
E
x
a
m
p
l
e
 
o
f
 
F
r
e
q
u
e
n
c
y
 
V
a
r
i
a
t
i
o
n
 
Figure shows Eastern Interconnect frequency
variation after loss of 2600 MWs
 
3
 
E
x
a
m
p
l
e
 
o
f
 
D
y
n
a
m
i
c
s
 
B
e
h
a
v
i
o
r
 
4
 
Source: August 14
th
 2003 Blackout Final Report
 
P
o
w
e
r
 
S
y
s
t
e
m
 
D
y
n
a
m
i
c
s
 
M
o
t
i
v
a
t
i
o
n
:
F
r
e
q
u
e
n
c
y
 
D
e
c
l
i
n
e
 
S
e
p
t
e
m
b
e
r
 
2
0
1
1
 
B
l
a
c
k
o
u
t
 
Image Source: Arizona-Southern California Outages on September 8, 2011 Report, FERC and NERC,April 2012
 
5
 
P
o
w
e
r
 
G
r
i
d
 
D
i
s
t
u
r
b
a
n
c
e
 
E
x
a
m
p
l
e
 
Time in Seconds
 
Figures show the frequency change as a result of the sudden loss of a
large amount of generation in the Southern WECC
 
Frequency Contour
Green is bus quite close to
location of  generator trip while
blue and red are quite distant.
 
6
 
R
e
c
a
p
:
 
P
o
w
e
r
 
F
l
o
w
 
The power flow is used to determine a quasi steady-
state operating condition for a power system
Goal is to solve a set of algebraic equations
g(y) 
=
 0  
[
y
 variables are bus voltage and angle]
Models employed reflect the steady-state assumption
Using a power flow, after a contingency occurs (such as
opening a line), the algebraic equations are solved to
determine a new equilibrium
 
7
 
P
o
w
e
r
 
F
l
o
w
 
v
s
.
 
D
y
n
a
m
i
c
s
 
Dynamics simulations is used to determine whether
following a contingency the power system returns to a
steady-state operating point
Goal is to solve a set of differential and algebraic equations,
d
x
/dt = 
f
(
x
,
y
) 
 
[
y
 variables are bus voltage and angle]
g
(
x
,
y
) = 
0
 
[
x
 variables are dynamic state variables]
Starts in steady-state, and hopefully returns to a new steady-
state value
Models reflect the transient stability time frame (up to dozens
of seconds)
Slow Values 
 Treat as constants
Ultra Fast States 
 Treat as algebraic relationships
 
8
 
P
o
w
e
r
 
S
y
s
t
e
m
 
T
r
a
n
s
i
e
n
t
 
S
t
a
b
i
l
i
t
y
 
In order to operate as an interconnected system all
of the generators (and other synchronous machines)
must remain in synchronism with one another
synchronism requires that (for two pole machines) the
rotors turn at exactly the same speed
Loss of synchronism results in a condition in which
no net power can be transferred between the
machines
A system is said to be transiently unstable if
following a disturbance one or more of the
generators lose synchronism
 
9
 
G
e
n
e
r
a
t
o
r
 
T
r
a
n
s
i
e
n
t
 
S
t
a
b
i
l
i
t
y
 
M
o
d
e
l
s
 
In order to study the transient response of a power
system we need to develop models for the
generator valid during the transient time frame of
several seconds following a system disturbance
We need to develop both electrical and mechanical
models for the generators
 
10
 
G
e
n
e
r
a
t
o
r
 
E
l
e
c
t
r
i
c
a
l
 
M
o
d
e
l
 
The simplest generator model, known as the
classical model, treats the generator as a voltage
source behind the direct-axis transient reactance;
the voltage magnitude is fixed, but its angle
changes according to the mechanical dynamics
 
11
 
G
e
n
e
r
a
t
o
r
 
M
e
c
h
a
n
i
c
a
l
 
M
o
d
e
l
 
Generator Mechanical Block Diagram
 
12
 
G
e
n
e
r
a
t
o
r
 
M
e
c
h
a
n
i
c
a
l
 
M
o
d
e
l
,
 
c
o
n
t
d
 
13
 
G
e
n
e
r
a
t
o
r
 
M
e
c
h
a
n
i
c
a
l
 
M
o
d
e
l
,
 
c
o
n
t
d
 
14
 
G
e
n
e
r
a
t
o
r
 
M
e
c
h
a
n
i
c
a
l
 
M
o
d
e
l
,
 
c
o
n
t
d
 
15
 
G
e
n
e
r
a
t
o
r
 
S
w
i
n
g
 
E
q
u
a
t
i
o
n
 
16
 
S
i
n
g
l
e
 
M
a
c
h
i
n
e
 
I
n
f
i
n
i
t
e
 
B
u
s
 
(
S
M
I
B
)
 
To understand the transient stability problem we’ll
first consider the case of a single machine
(generator) connected to a power system bus with
a fixed voltage magnitude and angle (known as an
infinite bus) through a transmission line with
impedance jX
L
 
17
 
S
M
I
B
,
 
c
o
n
t
d
 
18
 
S
M
I
B
 
E
q
u
i
l
i
b
r
i
u
m
 
P
o
i
n
t
s
 
 
19
 
T
r
a
n
s
i
e
n
t
 
S
t
a
b
i
l
i
t
y
 
A
n
a
l
y
s
i
s
 
For transient stability analysis we need to consider
three systems
1.
Prefault - before the fault occurs the system is assumed
to be at an equilibrium point
2.
Faulted - the fault changes the system equations,
moving the system away from its equilibrium point
3.
Postfault - after fault is cleared the system hopefully
returns to a new operating point
Actual transient stability studies can have
multiple events
 
20
 
T
r
a
n
s
i
e
n
t
 
S
t
a
b
i
l
i
t
y
 
S
o
l
u
t
i
o
n
 
M
e
t
h
o
d
s
 
There are two methods for solving the transient
stability problem
1.
Numerical integration
this is by far the most common technique, particularly for
large systems; during the fault and after the fault the power
system differential equations are solved using numerical
methods
2.
Direct or energy methods; for a two bus system this
method is known as the equal area criteria
mostly used to provide an intuitive insight into the transient
stability problem
 
21
 
S
M
I
B
 
E
x
a
m
p
l
e
 
Assume a generator is supplying power to an
infinite bus through two parallel transmission lines.
Then a balanced three phase fault occurs at the
terminal of one of the lines.  The fault is cleared by
the opening of this line’s circuit breakers.
 
22
 
S
M
I
B
 
E
x
a
m
p
l
e
,
 
c
o
n
t
d
 
Simplified prefault system
 
23
 
S
M
I
B
 
E
x
a
m
p
l
e
,
 
F
a
u
l
t
e
d
 
S
y
s
t
e
m
 
During the fault the system changes
 
The equivalent system during the fault is then
During this fault no
power can be transferred
from the generator to
the system
 
24
Slide Note
Embed
Share

In Lecture 23 of ECE 476, Prof. Tom Overbye discusses transient stability in power systems. Topics include power system time scales, frequency variations, dynamics behavior, grid disturbances, and power flow analysis. Announcements regarding assignments and exams are also highlighted.

  • Power System Analysis
  • Transient Stability
  • Prof. Tom Overbye
  • Power Grid Disturbance
  • Power Flow

Uploaded on Sep 13, 2024 | 1 Views


Download Presentation

Please find below an Image/Link to download the presentation.

The content on the website is provided AS IS for your information and personal use only. It may not be sold, licensed, or shared on other websites without obtaining consent from the author. Download presentation by click this link. If you encounter any issues during the download, it is possible that the publisher has removed the file from their server.

E N D

Presentation Transcript


  1. ECE 476 Power System Analysis Lecture 23: Transient Stability Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign overbye@illinois.edu

  2. Announcements Please read Chapters 11 HW 10 is 11.1, 11.4, 11.12, 11.19, 11.21; quiz on Dec 1 (hence it will not be turned in) We will be dropping your lowest two HW and/or Quiz scores Chapter 6 Design Project 1 is assigned. It will count as three regular home works and is due on Dec 3. For tower configurations assume a symmetric conductor spacing, with the distance in feet given by the following formula: (Last two digits of your EIN+150)/10. Example student A has an UIN of xxx65. Then his/her spacing is (65+150)/10 = 21.50 ft. Final exam is on Monday December 12, 1:30-4:30pm 1

  3. Power System Time Scales and Transient Stability Image source: P.W. Sauer, M.A. Pai, Power System Dynamics and Stability, 1997, Fig 1.2, modified 2

  4. Example of Frequency Variation Figure shows Eastern Interconnect frequency variation after loss of 2600 MWs 3

  5. Example of Dynamics Behavior Source: August 14th 2003 Blackout Final Report 4

  6. Power System Dynamics Motivation: Frequency Decline September 2011 Blackout Image Source: Arizona-Southern California Outages on September 8, 2011 Report, FERC and NERC,April 2012 5

  7. Power Grid Disturbance Example Figures show the frequency change as a result of the sudden loss of a large amount of generation in the Southern WECC 60 Green is bus quite close to location of generator trip while blue and red are quite distant. 59.99 59.98 59.97 59.96 59.95 59.94 59.93 59.92 59.91 59.9 59.89 59.88 59.87 59.86 59.85 59.84 59.83 59.82 59.81 59.8 59.79 59.78 59.77 59.76 59.75 59.74 59.73 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Time in Seconds Frequency Contour 6

  8. Recap: Power Flow The power flow is used to determine a quasi steady- state operating condition for a power system Goal is to solve a set of algebraic equations g(y) = 0 [y variables are bus voltage and angle] Models employed reflect the steady-state assumption Using a power flow, after a contingency occurs (such as opening a line), the algebraic equations are solved to determine a new equilibrium 7

  9. Power Flow vs. Dynamics Dynamics simulations is used to determine whether following a contingency the power system returns to a steady-state operating point Goal is to solve a set of differential and algebraic equations, dx/dt = f(x,y) [y variables are bus voltage and angle] g(x,y) = 0 [x variables are dynamic state variables] Starts in steady-state, and hopefully returns to a new steady- state value Models reflect the transient stability time frame (up to dozens of seconds) Slow Values Treat as constants Ultra Fast States Treat as algebraic relationships 8

  10. Power System Transient Stability In order to operate as an interconnected system all of the generators (and other synchronous machines) must remain in synchronism with one another synchronism requires that (for two pole machines) the rotors turn at exactly the same speed Loss of synchronism results in a condition in which no net power can be transferred between the machines A system is said to be transiently unstable if following a disturbance one or more of the generators lose synchronism 9

  11. Generator Transient Stability Models In order to study the transient response of a power system we need to develop models for the generator valid during the transient time frame of several seconds following a system disturbance We need to develop both electrical and mechanical models for the generators 10

  12. Generator Electrical Model The simplest generator model, known as the classical model, treats the generator as a voltage source behind the direct-axis transient reactance; the voltage magnitude is fixed, but its angle changes according to the mechanical dynamics V E X T a ( ) = sin P e ' d 11

  13. Generator Mechanical Model Generator Mechanical Block Diagram = = = = = + + ( ) T T J T T m m D e mechanical input torque (N-m) moment of inertia of turbine & rotor angular acceleration of turbine & rotor damping torque equivalent electrical torque = m J m T T ( ) D e 12

  14. Generator Mechanical Model, contd In general power = torque angular speed Hence when a generator is spinning at speed T J T T J T P J T = + s = = + + ( ) ( )) e T + T m m D e + + ( P s s m m D m ( ) P s s m m D e = Initially we'll assume no damping (i.e., Then P P ( ) is the mechanical power input, which is assumed to be constant throughout the study time period 0) T D = J s m e m P m 13

  15. Generator Mechanical Model, contd ( ) = P P J + s m e m = = rotor angle t m s d m = = = + m m s dt = = m P m ( ) = = P J J s s m e m = inertia of machine at synchronous speed Convert to per unit by dividing by MVA rating, ( ) 2 m e s P P J S S S 2 s J s , S B s = B B B 14

  16. Generator Mechanical Model, contd ( ) S 2 2 P S P J s m e s = S B B B s 2 s ( ) 1 P P J m e = = (since 2 ) f s s 2 S S f B B s 2 s J = Define H per unit inertia constant (sec) 2 S B All values are now converted to per unit H P P f P P H ( ) = = Define M m e f s s = M Then ( ) m e 15

  17. Generator Swing Equation This equation is known as the generator swing equation ( ) Adding damping we get ( ) This equation is analogous to a mass suspended by a spring = P P M m e = + P P M D m e = + kx gM Mx Dx 16

  18. Single Machine Infinite Bus (SMIB) To understand the transient stability problem we ll first consider the case of a single machine (generator) connected to a power system bus with a fixed voltage magnitude and angle (known as an infinite bus) through a transmission line with impedance jXL 17

  19. SMIB, contd E + a ( ) = sin P e ' X X d L E + a + = sin M D P M ' X X d L 18

  20. SMIB Equilibrium Points Equilibrium points are determined by setting the right-hand side to zero E + a + = sin M D P M ' X X d L E + a = sin 0 P M ' X X d L X ' = + Define X X th d L P X E 1 M th = sin a 19

  21. Transient Stability Analysis For transient stability analysis we need to consider three systems Prefault - before the fault occurs the system is assumed to be at an equilibrium point Faulted - the fault changes the system equations, moving the system away from its equilibrium point Postfault - after fault is cleared the system hopefully returns to a new operating point 1. 2. 3. Actual transient stability studies can have multiple events 20

  22. Transient Stability Solution Methods There are two methods for solving the transient stability problem Numerical integration this is by far the most common technique, particularly for large systems; during the fault and after the fault the power system differential equations are solved using numerical methods Direct or energy methods; for a two bus system this method is known as the equal area criteria mostly used to provide an intuitive insight into the transient stability problem 1. 2. 21

  23. SMIB Example Assume a generator is supplying power to an infinite bus through two parallel transmission lines. Then a balanced three phase fault occurs at the terminal of one of the lines. The fault is cleared by the opening of this line s circuit breakers. 22

  24. SMIB Example, contd Simplified prefault system The prefault system has two equilibrium points; the left one is stable, the right one unstable P X E 1 M th = sin a 23

  25. SMIB Example, Faulted System During the fault the system changes The equivalent system during the fault is then During this fault no power can be transferred from the generator to the system 24

Related


More Related Content

giItT1WQy@!-/#giItT1WQy@!-/#giItT1WQy@!-/#giItT1WQy@!-/#giItT1WQy@!-/#giItT1WQy@!-/#