NAVSEA.05Z Electrical Systems Technical Update - NSRP Initiatives and Priorities
Update on NAVSEA.05Z electrical systems technical initiatives and priorities, including standards and specifications projects supported by NSRP. Highlights key high-priority items related to circuit breaker obsolescence, cable supply shortages, and product qualification testing. Discusses fire-resistant qualification test requirements for cable transits and sealants, with a focus on MIL-DTL-24705B and MIL-I-3064. Emphasizes the need for funding to update specifications and resolve test plan approval issues to address product supply chain challenges.
Download Presentation
Please find below an Image/Link to download the presentation.
The content on the website is provided AS IS for your information and personal use only. It may not be sold, licensed, or shared on other websites without obtaining consent from the author. Download presentation by click this link. If you encounter any issues during the download, it is possible that the publisher has removed the file from their server.
E N D
Presentation Transcript
NAVSEA 05Z3 Electrical Systems Technical Update Presented at the National Shipbuilding Research Program Electrical Technologies Panel Meeting August 10, 2022 Christopher Nemarich Engineering Manager Electrical Systems Ships SEA 05Z33 NAVAL SEA SYSTEMS COMMAND DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.
NAVSEA 05Z Update to NSRP NAVSEA 05Z3 Initiatives and Priorities Summary of Standards and Specifications Projects NSRP Electrical Technologies Projects Supported DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.
NAVSEA 05Z Update to NSRP NAVSEA 05Z High Priority Items SEA 05Z is working with NSWC PD on numerous issues related to Circuit Breaker Obsolesce and Qualification Testing Requirements Shortages of available MIL-DTL-24643 and MIL-DTL-24640 Electrical Cable Supply Chain and Qualification and Requalification Issues of MIL-DTL- 24705B MCTs andMIL- I-3064 Plastic Sealer Backlog of over-age specifications / standards / technical manuals and drawings Widespread qualified product obsolescence and vendor unwillingness to continue product qualification testing for RSL lighting components and instrumentation pressure transducers, salinity measurement and panel meters Supporting FFG 62 design reviews DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.
NAVSEA 05Z Update to NSRP Multi Cable Transits and Sealants Fire Resistant Qualification Test Requirements for MIL-DTL-24705B Penetrators, Multiple Cable, Electric Cable (MCTs) 24705/1, 24705/3 and 24705 /4 MIL- I-3064 Insulation Electrical Plastic Sealer Bothrequire new test requirements for both the qualification and retention testing. Fire stop test requirements of MIL-STD-3020 Appendix D. Cable Transit Test Configuration and Appendix F have been invoked. Funding is needed to update the specifications. Shock Testing is required prior to Fire Resistance Test for QPL products to requalify. This change impacts QPL Approval for Existing and New Cable Transits, Sealing Systems and Sealants. Multiple TWH Stakeholder concurrence is required and has been obtained. Warfare Center review of both Qualification and Retention Test Requirements and the Submitted Vendor Test Plans is needed. NAVSEA is working to resolve the test plan review approval issues to get comments to Vendors and allow test plan to relieve product supply chain issues and new qualification of the NSRP developed MCTs and Sealing Systems. DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.
MIL SPECS, STANDARDS, DRAWINGS Specification and Standard Update Efforts Highlights MIL-STD-108 Definitions Basic Requirements Enclosures for Electric and Electronic Equipment Last updated in 1985 but no significant changes since 1966 Updating all reference documents e.g. IEC 60947-1 De-conflicting with MIL-DTL-2036 and adding reference to Composite Enclosures Incorporating IP and NEMA equivalent comparisons to the definition table Equipment vendors and electrical designers with the shipbuilders are needed for SRB review of proposed changes MIL-DTL-15103 Salinity Indicating Equipment Revisions required to address age of spec and obsolescence issues. Revisions to test requirements SRB Comments Received and are being addressed Review and Adjudication of Comments underway New system for LHA / LHD in underway trials new performance spec to replace 15103 will be needed to allow for modernization of salinity measurement. 5 DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.
MIL SPECS, STANDARDS, DRAWINGS Electrical Cables / Assemblies / Connectors MIL-DTL-24643 Cables, Low Smoke SEA 08K review (base spec only) Slant Sheets are being revised and readied for SRB. MIL-DTL-24640 Cables, Lightweight, Low Smoke (Base spec + all slant sheets) Project in progress MIL-HDBK-299Electrical Cable Comparison Handbook - October 1991 CableData Pertaining to Electric Shipboard Cable Revisions / updates for intermediate review are being developed Include cables new to MIL-DTL- 24643 and MIL-DTL-24640 and other new cables MV cables (rated 5 KV and 15 KV) to be included in addition to LV rated cables (<1KV) NEMA Cable manufacturers are being added to the SRB reviewer list NSRP and NAVY end users and designers are encouraged to do SRB review of proposed changes 6 DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.
MIL SPECS, STANDARDS, DRAWINGS Switchboards MIL-DTL-32483A Switchgear, Power, Hard-Mounted, Medium Voltage, Naval Shipboard In review prior to publication MIL-DTL-xx653 Switchgear, Power, Shock-Mounted, Low Voltage, Naval Shipboard Incorporating comments prior to publication MIL-DTL-16036N Switchgear, Power, Low Voltage, Naval Shipboard Part 1 (Interim Amendment); Part 2 (Revision) Remains unfunded Circuit Breakers MIL-DTL-17361H - Circuit Breaker Types AQB/NQB, Air, Electric, Low Voltage, Insulated Housing (Shipboard Use) At NAVSEA 08 Review MIL-DTL-17588F Breakers (ALB-1) and Switch, Toggle (Circuit Breaker, NLB-1) Air, Insulated Housing, 125 Volts and Below AC and DC (Naval Shipboard Use) At NAVSEA 08 Review MIL-DTL-17361H /1C - /19 - Circuit Breaker Types AQB/NQB NSWC PD has for review 7 DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.
MIL SPECS, STANDARDS, DRAWINGS Circuit Breakers MIL-DTL-17587D /3A /5A and /6A - Circuit Breakers, ACB, Low Voltage, Electric Power, Air, Removable Construction In Final review UL 489D US Naval COTS Designated Molded-Case Circuit Breakers and Accessories for Use on Non Nuclear Naval Combatant Ships UL 1066A US Naval COTS Designated Three-Pole Low-Voltage AC Power Circuit Breakers, Drawout-Mounted Type, and Accessories / Functional Components for Use on Non-Nuclear Naval Combatant Ships Comments in review and adjudication. 8 DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.
MIL SPECS, STANDARDS, DRAWINGS Lighting MIL-DTL-16377 Fixtures, Lighting; and Associated Parts; NEW MIL-DTL-16377K Base Spec Published 03-May-2022 Revised design and test requirements for SSL based on lessons learned and on testing and compliance issues raised by industry suppliers Clarified and eliminated test requirement ambiguities and updated life expectancy requirements to match Illumination Engineering Society (IES) Standards. MIL-DTL-16377/60B Incandescent, Floodlights, 150 Watts, 120 Volts, Sym 316 / 317 Published 25-Jan-2022 Hooded Spotlights Did not update flood lights to include an SSL version due to incompatibility issues with dimming circuitry. Will need to revisit to resolve requirement and design issues to allow SSL MIL-DTL-16377/61A Incandescent and Solid-State Floodlights, 300 W, 120 V, Sym 303.2, 303.3, 303.4, 303.2SSL, 303.3SSL, 303.4SSL Eliminated EMI requirements and reduced Shock & Vibe to Grade B Published 02-Nov-2021 MIL-DTL-16377/86B Fixtures, Lighting; Lamp, Solid-State, for use as Replacement for Commercial Fluorescent Lamp Published 02-Nov-2021 Includes additional SSL lamp styles to support more back-fits 9 DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.
MIL SPECS, STANDARDS, DRAWINGS Lighting MIL-DTL-16377 K Fixtures, Lighting; and Associated Parts Updated T8 Fluorescent fixtures to include reference to the T12 fixture slant sheets for the equivalent form, fit and function SSL option. Publication expected AUG 2022 MIL-DTL-16377/78A T8 Fluorescent, General Lighting, 17 Watts, Sym 331.1T8, 331.2T8, and 347.3T8 MIL-DTL-16377/79A T8 Fluorescent, General Lighting, 34 Watts, Sym 77.4T8, 77.5T8, 344.2T8, and 344.3T8 MIL-DTL-16377/80A T8 Fluorescent, General Lighting, 51 Watts, Sym 333.1T8, 333.2T8, 341.1T8, 341.2T8, 333.1T8RC, 341.4T8, 342.2T8, and 342.3T8 MIL-DTL-16377/82A T8 Fluorescent, Emergency Lighting, 17 Watts, Sym 331.1T8EM, 331.2T8EM, 347.2T8EM, and 347.3T8EM MIL-DTL-16377/83A T8 Fluorescent, Emergency Lighting, 34 Watts, Sym 77.4T8EM, 77.5T8EM, 344.2T8EM, and 344.3T8EM MIL-DTL-16377/84A T8 Fluorescent, Emergency Lighting, 54 Watts, Sym 333.1T8EM, 333.2T8EM, 342.2T8EM, and 342.3T8EM 10 DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.
MIL SPECS, STANDARDS, DRAWINGS Lighting MIL-DTL-16377 K Fixtures, Lighting; and Associated Parts Adding SSL to 13 slant sheets as options for incandescent and fluorescent lamps. Added USB option to 16377/17 Beth lights. MIL-DTL-16377/53D Light Emitting Diode (LED), Lantern, Hand, Portable and Bulkhead Mounted, Watertight, Sym 100.2L, 101.2L, 101.3L Deleted ALL incandescent lanterns at direction of the NAVSEA CHENG (2012) Deleted option for rechargeable portable lanterns Deleted DC and higher voltage powered lanterns - no longer used Revised the design requirements to provide operational and maintenance improvements Thanks to Jason Farmer for providing Photometric Array Testing of the SSL White and Red Arrays for inclusion in the revised slant sheet. Reviewing inactivation of multiple slant sheets for obsolete or little used fixtures. Revising requirements for and adding SSL options to portable lights 11 DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.
MIL SPECS, STANDARDS, DRAWINGS Lighting NSTM Chapter 330 S9086-K9-STM-010/330 Rev 5 Added documentation to Appendix B on procedure to correct wiring on retrofit Battle Lantern battery charger circuits. Updated Table A-1 Available LED Tubes to Replace Fluorescent Lamps Expected Publication late FY22 12 DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.
MIL SPECS, STANDARDS, DRAWINGS Lighting What is this? Any guesses? 13 DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.
MIL SPECS, STANDARDS, DRAWINGS Lighting Here s a hint 14 DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.
MIL SPECS, STANDARDS, DRAWINGS Lighting How s this? Better now? 15 DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.
MIL SPECS, STANDARDS, DRAWINGS Topside and Navigation Lighting Funding needed to review and update requirements to allow RSL and SSL Advanced Top Side and Navigation Lighting. Governing specifications are inadequate to address the test and qualification of solid state lights. Need to address COLREGs to resolve compliance concerns. MIL-DTL-24560 Lights and Glassware for Navigation, Signal, and Warning, Naval Shipboard; slant sheets /1 to /10 and /16 to /26 5 Feb 1999 - requires revision to allow SSL versions MIL-C-24174 Control, Navigation Lights, General Specification for; /3 and /4 Oct 1987 MIL-S-19551 Searchlight, Incandescent & Mercury-Xenon Vapor Lamp, Signaling, 12 MIL-S-2649 Searchlight, Incandescent, 7-Inch Sealed Beam Lamp for Small Boats There are no requirements for SSL replacements of these but better performing SSL alternatives exist and have been adopted for some selected applications. MIL-P-24175 Panel, Power Supply and Control for Navigation Lights 27-Aug-1971 Not compatible with SSL and RSL topside ligating control. A replacement MIL-PERF is required. MIL-HDBK-289 LIGHTING ON NAVAL SHIPS - 26 Nov 1986 Funding requested for FY23 PRIORITY TO ALLOW SSL DESIGNS FOR NEW CONSTR This remains unfunded. 16 DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.
NSRP Electrical Technology Panel Projects 05Z NSRP Recent Projects Cable Penetration test and qualification to MIL-DTL-24705 Cable Penetration sealant test and qualification to MIL-I-3064 Shore Power Cable Connector Test Set development DTS Distributed Temperature Sensing for MV Switchboard Monitoring Advanced Top Side Lighting Requirements needed to support Organic LED and Low Voltage Lighting Future Design / Production Electrical Connector Standardization Shipboard Cable Tray Improvements 17 DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.
NSRP Electrical Technology Panel Projects Questions? 18 DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.