SN65HVD33 Load Tests Aug. 2018
Conducted load tests on SN65HVD33 device with specific test conditions including Vcc=3.3V, termination of 120 Ohm, PRBS data at 26Mbps, CAT5 cable of 1 foot length, and load of 200 Ohm. Analyzed Vpp of A-B and Rout under different load conditions. Detailed results and analysis presented in images.
Download Presentation
Please find below an Image/Link to download the presentation.
The content on the website is provided AS IS for your information and personal use only. It may not be sold, licensed, or shared on other websites without obtaining consent from the author. Download presentation by click this link. If you encounter any issues during the download, it is possible that the publisher has removed the file from their server.
E N D
Presentation Transcript
SN65HVD33 load tests ASC/INT/TRX Aug 2018 1
Test condition Device: SN65HVD65 Vcc=3.3V Room temperature Termination: 120Ohm PRBS data (26Mbps) CAT5 cable (1 feet) Load: 200Ohm (equivalent to about 100 RX nodes) 2
Vpp of A-B With no load With load 3
Vpp of Rout With no load With load 4